DATA SHEET 08
WIRING INSTRUCTIONS FOR 2-4 PAIR CABLES
IF 2-4 pair telephone cables will be installed, then use these
instructions instead of the instructions in SECTION II pages 6 & 7 and DATA SHEET
03 page 17 from this manual. It is recommended in the case of 2-4 pair cables
being used that different color outer insulation be used to aid in installation.
A. See SECTION II STEP 2 page 5 for diagram to connect station wire to the power
supply.
B. Feed wire through the clamp located on the end of the
top cover.
C. Strip the outer jacket off the wire about 6 inches.
D. Strip the insulation off each wire about 1 inch. Be careful not to nick the
wire
when stripping.
E. Connect the following six wires from cable #2 to TB1 Pin 1 - +5VDC:
WHITE with BLUE, WHITE with ORANGE
GREEN with WHITE, WHITE with GREEN
BROWN with WHITE, WHITE with BROWN
F. Connect the following six wires from Cable #1 to TB2 Pin 1 - GND:
WHITE with BLUE, WHITE with ORANGE
GREEN with WHITE, WHITE with GREEN
BROWN with WHITE, WHITE with BROWN
Repeat steps B through F, changing steps E and F to the next available pin on TB1 &
TB2, until all station wires are connected.
G. Connect all BLUE with WHITE wires from each station cable (cable #1) to
TB1 Pin 8 - DATA1.
H. Connect all ORANGE with WHITE wires from each station cable (cable #1) to
TB2 Pin 8 - STATUS1.
The BLUE with WHITE and ORANGE with WHITE wires from cable #2 are not used!!
|
|